67 Signs and Causes of Equipment Malfunction

67 Signs and Causes of Equipment Malfunction Learning Objectives Identify signs and isolate causes of malfunction and list corrective actions. A sign AND cause of equipment malfunction is miscalibration. Calibration Using measuring equipment to measure something of known value to see if the measuring equipment is accurate. Calibration Needs in a Food Plant: - All equipment and instruments used for ensuring safety, quality, sanitation, and regulatory compliance must be calibrated. - Calibration ensures the equipment readings are accurate and give control of the process. - Can contract with the external supplier or conduct in-house - Needs to have in-house support and management even if contracted. To achieve this: - Develop effective procedures for calibration - Document the procedures in SOPs - Maintain records of calibration activities, including corrective actions - Verify to ensure that procedures are being followed - Put someone in charge The following is an example SOP documenting the procedure of calibrating a scale. This document is accessible at: PROCEDURE FOR CALIBRATING, STANDARDIZING, OR CHECKING EQUIPMENT Revised 06/16 PROCEDURE #46 Equipment Checked: Scales (Balances) Reference Documents: NIST Handbook 44, AASHTO M231, ASTM E617, ASTM C138 Purpose: To provide instructions for checking the accuracy of scales to be used in area and project labs. All scales shall be checked annually. Inspection Equipment: Suggested standard weights (checked against calibrated scale) 100g, 200g, 5kg, 10kg, 20kg. Tolerance: The allowable tolerance throughout the range checked shall be equal to or less than 0.1% of the test load. The allowable tolerance for Platform scales used to determine fresh concrete unit weight shall be equal to or less than 0.3% of the test load. Procedure: - Set up the scale in a location away from drafts or excessive air movement. - Level the scale, and if weighing underwater, observe that the apparatus is free of any obstruction that may affect its movement. - Perform Span Check: Place the verification weights in the center of the scale. Record the weight to the readability of the scale. Confirm repeatability by placing one of the weights on the scale a second time to obtain the same weight. Confirm that the reading returns to zero when the weights are removed. - For weighing devices with a capacity of up to 1,000 grams, the suggested verification weights are 100g and 200g. External scale calibration weight shall be 200g. - For 12kg weighing devices, suggested verification weights of 5kg and 10kg. External scale calibration weight shall be 10kg. - For 30kg weighing devices, suggested verification weights of 10kg, and 20kg. External scale calibration weight shall be 20kg. - For platform weighing devices used for standard density determination, the suggested verification weights are 10kg and 20kg. Note: It is desirable to perform additional checks on scales for accuracy after they have been installed in the construction field lab.
← Previous Chapter Next Chapter →