Chapter 8. Intravenous Therapy

Chapter 8. Intravenous Therapy 8.6 Infusing IV Fluids by Gravity or an Electronic Infusion Device (Pump) To ensure therapeutic effectiveness of IV fluids, a constant, even flow is necessary to prevent complications from too much or too little fluid. A prescriber must order a rate of infusion for IV fluids. The rate of infusion for medications (given via a secondary or primary infusion) can be found in the Parenteral Drug Therapy Manual (PDTM). If an order for IV fluids is “to keep vein open” (TKVO), the minimum flow rate is 20 to 50 ml per hour, or according to physician’s orders (Fraser Health Authority, 2014). A healthcare provider is responsible for regulating and monitoring the amount of IV fluids being infused. IV fluid rates are regulated in one of two ways: - Gravity: The healthcare provider regulates the infusion rate by using a clamp on the IV tubing, which can either speed up or slow down the flow of IV fluids. An IV flow rate for gravity is calculated in gtts/min. - Electronic infusion device (EID) (see Figure 8.20): The infusion rate is regulated by an electronic pump to deliver the fluids at the correct rate and volume. All IV pumps regulate the rate of fluids in ml/hr. An IV pump (EID) is used for many types of patients, solutions, and medications (Vancouver Coastal Health, 2008). These devices include a variety of safety features including alerts for air and occlusions, a medication administration library, the ability to calculate infused volumes, and back up battery power. An EID / IV pump must be used: - Whenever possible to avoid some complications associated with IV therapy - With all opioid infusions (use a patient-controlled analgesia) - For all pediatric patients - As directed in the PDTM To calculate the drops per minute for an infusion by gravity, follow the steps in Table 8.9. Remember that you only have to do this when you are running the IV by gravity. Table 8.9 Calculating the Drops per Minute (gtts/min) for an Infusion by Gravity | ||||||||| Steps | Additional Information | |||||||| | 1. Verify the physician’s order. | An order may read: | |||||||| | 2. Determine the drop factor on the IV administration set. | The drop factor is the amount of drops (gtts) per minute. IV tubing is either macro tubing (10, 15, or 20 gtts/min) or micro tubing (60 gtts/min). The drop factor (or calibration of the tubing) is always on the packaging of the IV tubing. | |||||||| | 3. Complete the calculation using the formula. | Use the formula: To calculate ml/hr, divide 1000 ÷ 8 = 125 ml/hr. Example: Infuse IV NS at 125 ml/hr. IV tubing drop factor is 20 gtts/min | |||||||| | 4. Regulate IV infusion using the roller clamp. | With tubing already primed, open the blue roller clamp and count the drips in the drip chamber and regulate for 42 gtts/min (one full minute). Alternatively, divide 42 by 4 (rounded down from 10.4 to 10 gtts/min) to count for 15 seconds. The gtts/min should be assessed regularly to ensure the IV is infusing at the corr
← Previous Chapter Next Chapter →